Ji Japsin Instrumentation Negative Temperature Calibrator Dry Block Bath
Minimum Order Quantity: 1 Piece
Product Brochure
Model Number/Name | JI-30-125 |
Accuracy | 0.5% |
Application | Temperature Calibration |
Brand | Japsin Instrumentation |
Weight | 8.5 Kgs |
Power Supply | 230 Vac |
Display Type | Digital |
Color | Blue |
Model Number | Ji-30-125 |
Temperature Range | -30 to 125 Deg C |
Warranty | 1 Year for Any Manufacturing Defects |
TEMPERATURE CALIBRATION BATH LOW RANGE -30 TO 125 DEG C (DRY BLOCK TYPE) , MODEL SEC-LT-30125
DESCRIPTION
The Test instrument consist of two single enclosures. Front size 150 X 150 mm & 280 mm depth. They are connected with each other & equipped with a portable handle. The left enclosure contains a block with bore diameter of 18.5 mm & 110 mm depth which can reached from the top, face the reception of the test piece. In this block the heating cartridge & temperature sensor for the determination of the block temperature are installed / accesses from the bottom.
The right enclosure contains:
1) PID controller for control of the block temperature in which we can see the set value & present temperature of the block.
2) Power switches & power on indicator
3) Fan ON / OFF switch for cooling the block.
ADAPTER POCKETS:
It has to be made sure that the heat transmission resistance between the heating block & the test piece (thermometer, temperature sensor, temperature switch) is as low as possible. Therefore it is necessary to use exactly adapted pockets.
TECHNICAL DATA:
Regulation of the heating block
PID regulator
Temperature Range
-30 to 125 deg C
Power Supply
230 V AC, 50 Hz.
Power consumption
1000 Watts
Accuracy
+/- 0.5 Deg C
DIMENSIONS:
Block Bore ID
18.5 mm
Immersion length
110 mm
4 numbers of Adapter pocket are provided extra with the following sizes
1) ID
6.1 mm
2) ID
8.1 mm
3) ID
10.1 mm
Size of the instrument
150 X 300 X 280 mm
Weight of the instrument
Approx. 8.5 Kg
Additional Information:
- Item Code: JI-30-125
- Production Capacity: 5000
- Delivery Time: 7 Days
- Packaging Details: Export Quality
Ji Japsin Instrumentation Temperature Calibrator Dry Block Bath For 650 Deg C
Minimum Order Quantity: 1 Piece
Product Brochure
Accuracy | 0.5% |
Model Number/Name | TB-600 |
Temperature Range | Ambient to 600 / 650 Deg C |
Display Type | Digital |
Range | Ambient to 600 / 650 Deg C |
Brand | "Ji" Japsin Instrumentation |
Weight | 8.5 Kg/Cm2 |
I deal in | New Only |
We are well known manufaturer of Temperature Calibration Bath , which also konwn as Dry Block Temperature Calibrator.
The Test instrument Temperature Calibration Bath consist of two single enclosures. Front size 150 X 150 mm & 280 mm depth. They are connected with each other & equipped with a portable handle. The left enclosure contains a block with bore diameter of 18.5 mm & 110 mm depth which can reached from the top, face the reception of the test piece. In this block the heating cartridge & temperature sensor for the determination of the block temperature are installed / accesses from the bottom.
The right enclosure contains:
PID controller for control of the block temperature in which we can see the set value & present temperature of the block.
Power switches & power on indicator
Fan ON / OFF switch for cooling the block.
Operating Instructions:
The test instrument TB - 600 is a portable unit for service / calibrating / testing purpose as well as for operating & laboratory tasks.
After switching on the mains power switch the PID controller shows the temperature of the block. (PV). Below that green color LED shows the set value of the block (SV). To adjust the set point, press key (2) then a dot LED blinks near the first digit, then using up key (3) & down key (4) set the 0 - 9 digit again push the (2) key to move the dot LED to the second digit using up & down key. After setting the set point value press the set (1) key for setting the temperatures. For auto tuning press (2) key for 2 seconds the 'At' from OFF to ON. Then press (1) key to active the auto tuning process, During auto tuning, the instrument executes on contr. After 2 cycles of ON - OFF action, the instrument will obtain the values of PID parameters. If you want to escape from auto tuning status, press& hold key (2) for about 2 seconds until 'At' parameters appear again. Change 'At' from 'ON' to 'OFF', press (1) key to confirm, then the auto tuning process will be cancelled.
The PV shows continuously the temperature of the heating block. If the adjusted set temperature in the heating block is reached, the heating energy radiated from the block is dispensed by short switching on pulses of the heating cartridge, so the temperature inside the block is kept constant.
Cooling down the heating lock can be done quickly by switching ON the fan which produces higher amount of cooling air.
Adapter Pockets:
It has to be made sure that the heat transmission resistance between the heating block & the test piece (thermometer, temperature sensor, temperature switch) is as low as possible. Therefore it is necessary to use exactly adapted pockets.
Technical Specifications:
Regulation of the heating block: PID regulator
Temperature Range: Room temperature to 600 Deg C
Power Supply: 230 V AC, 50 Hz.
Power consumption: 1000 Watts
Accuracy: /- 0.5 Deg C
Additional Information:
- Item Code: TB-600
- Pay Mode Terms: T/T (Bank Transfer)
- Port of Dispatch: Mumbai
- Production Capacity: 40000
- Delivery Time: 7 days
- Packaging Details: Export Quality
Ji Japsin Instrumentation 1200 Deg C High Range Temperature Calibrator Dry Block Bath
Minimum Order Quantity: 1 Piece
Product Brochure
Model Number/Name | JI-1200 |
Brand | Japsin Instrumentation |
Accuracy | 0.5% |
Display Type | Digital |
Application | High Range Temperature Calibrator |
Weight | 10 kgs |
Model Number | JI-1200 |
Warranty | 1 Year For Any Manufacturing Defects |
Usage/Application | Temperature Gauges Calibrator |
Purpose: A Temperature Calibration bath is used to obtain precise temperature for calibration of RTD’s, (LIG) Liquid in Glass Thermometer, Thermocouples & PRTs, SPRTs. Temperature Calibration baths are electric controllers which are in high reliability & accuracy in the measuring Temperature. Temperature Calibration Bath is particularly suitable for calibration of the widest range of Temperature Gauges or Instruments.
Additional Information:
- Delivery Time: 7 Days
- Packaging Details: Export Quality
Ravika Dead Weight Pressure Gauge Tester
Product Brochure
Minimum Order Quantity | 1 Box |
Calibration Interval | Yearly |
Material | MS & SS |
Brand | Japsin Instrumentation,Ravika |
Calibrated For | Customer Requirement |
Industry Type | Calibration |
Brand/Model | DW Series |
Accuracy | 0.1 |
Pressure | As Required |
Usage/Application | Pressure Gauge Calibration |
For calibration of Pressure Gauges and other sensing, transmitting and recording pressure instruments, we offer Dead Weight Pressure Gauge Tester. Relationship between pressure acting on the known area of a vertically free floating piston producing a force balanced by known dead weight is made use of in the Dead Weight Pressure Gauge Tester.
The main components of a Dead Weight Pressure Gauge Tester are
Screw Pump to generate pressure in the circuit. Of adequate capacity and operated by turning the spoked handle. Permits easy and accurate setting of pressure.
Free Piston Assembly of special steel, hardened, tempered, ground and lapped to accurate size and very fine surface finish to provide true floating action.
Set of Weights directly marked in convenient values of pressure and easily stacked on the carrier weight. Available in either/and kgf/cm2, bar Cbf/in units. Other units on request. Storage box provided. Incremental weights to provide smaller steps available at extra cost for all models mentioned below.
Gauge Connector of 1/2" BSP (female) union for connecting gauge to be tested. Other sizes of gauges can be connected by using adaptors.
Baseplate of sturdy construction provided with legs and levelling screws. The entire circuit is protected by a Sheet Metal Cover.
Additional Information:
- Item Code: DW
- Port of Dispatch: MUMBAI
- Production Capacity: 50
- Delivery Time: 6 weeks
- Packaging Details: Wooden Box Packing
Japsin Instrumentation Handheld Hydraulic Pressure Calibrator
Minimum Order Quantity: 1 Piece
Product Brochure
Model Number/Name | HP-700 |
Brand | "Ji" Japsin Instrumentation |
Application | Industrial |
Usage/Application | Pressure Calibrator |
Range | 0 to 700 Kg/Cm2 |
Accuracy | 0.25% |
Power Source | By Hand |
Warranty | 1 Year Manufacturing warranty |
Weight Kg | 2 Kgs |
I deal in | New Only |
Descriptions :
1. Lightweight hand held hydraulic pressure pump.
2. Pressure can be generated with fewer strokes by hand.
3. Generates pressure up to 400 Kg/cm2 / Bar with Water or 700 Kg/cm2 or Bar with Oil
4. Top ½ ” BSP (F) adopter for the Master gauge.
5. Side flexible tubing with ¼” BSP (F) adopter for gauges to be tested.
6. Side release knob for pressure.
7. Side zero adjuster knob
8. Hydraulic Oil container
Additional Information:
- Item Code: HP-700
- Production Capacity: 5000
- Delivery Time: 7 Days
- Packaging Details: Export Quality
JI Japsin Instrumentation JI-VP-115 Pneumatic Handheld-Portable Vacuum Cum Pressure Calibrator
Minimum Order Quantity: 1 Piece
Product Brochure
Model Name/Number | JI-VP-115 |
Test Connection Port | 1/4" BSP (F) |
Usage/Application | Laboratory |
Country of Origin | Made in India |
Material | SS |
Display Type | Digital |
Type | Handheld |
Accuracy | 0.5% |
Range | -0.95 to 15 Bar |
Spares | Adaptor Provided |
Range -0.95 to 15 Bar
Supplied along with Calibration Certificate Traceable To National Standard
Additional Information:
- Production Capacity: 500
- Delivery Time: 7 Days
Japsin Instrumentation Handheld Pneumatic Vacuum Cum Pressure Calibrator
Minimum Order Quantity: 1 Piece
Product Brochure
Model Name/Number | JI-VP-140, JI-VP-140 |
Material | SS 316 |
Display Type | Analog |
Application | Laboratory |
Type | Portable |
Usage/Application | Vacuum Cum Pressure Gauge |
Range | -1 to 40 Kg/Cm2 |
Brand | "Ji" Japsin Instrumentation |
Accuracy | Depending upon the Master Gauge |
Power Source | By hand Mechanical |
Warranty | 1 Year Manufacturing warranty |
Weight Kg | 3 kg/cm2 |
Vacuum Range | Full Vaccum |
I deal in | New Only |
Country of Origin | Made in India |
Range -1 to 40 Bar
Light Weight Easy to Operate. Pneumatic Application Calibrator
Additional Information:
- Item Code: JI-VP-140
- Production Capacity: 5000
- Delivery Time: 7 days
- Packaging Details: Carrying Case Included
Ravika Dead Weight Vacuum Gauge Tester
Minimum Order Quantity: 1 Piece
Product Brochure
Brand | Ravika |
Material | SS / MS |
Model Number/Name | DT-55 |
Usage/Application | Vacuum Gauge Calibrator |
Packaging Type | Carrying Case Provided |
Display Type | Analog |
Brand/Model | Japsin Instrumentation |
Grade | Manual |
Weight | 70 Kg/Cm2 |
Pressure | 0 to 760 mmhg |
Measuring Range | Full Vacuum |
I deal in | New Only |
We offer Dead Weight Vacuum Gauges Tester. Model Dt-56 is used for calibration of vacuum gauges and other sensing, transmitting and recording vacuum instruments. The Vacuum Gauge Tester is a quick and convenient method of calibration free from the disadvantages of using the fragile mercury manometer.
The main components of the tester are:
Screw Pump: To generate the vacuum in the tester conveniently and precisely. Of adequate capacity and operated by turning the spoked handle.
Free Piston: Assembly of special steel, hardened, tempered, ground and lapped to accurate size and very fine surface finish to provide true floating action. The free piston is suspended vertically downwards from a rigid frame and connected by a pipe to the screw pump. A CARRIER weight is attached to the free piston for taking more weights.
Valve: It is provided to connect the circuit to the atmosphere and thus check zero of the gauge.
Gauge Connector: It is of ½' BSP (female) union for connecting gauge to be tested. Other sizes of gauges can be connected by using adaptors.
Technical Specifications:
Minimum Vaccum
Smallest Step
Maximum Vaccum
Unit
0.1
0.02
0.96
kgf/cm2
50
10
710
mmHg
2
0,5
28
inHg
Features of Model CT5:
Range: 0-710 mm Hg
For quick calibration with Master Gauge. The master gauge to be periodically checked on Dead Weight Vacuum Gauge Tester.
Two guage connectors are provided for connecting master and gauge to be tested to the same vacuum.
Screw pump is provided to generate vacuum in the circuit. Permits easy and accurate setting of vacuum.
Valve is provided to connect the circuit to the atmosphere and thus check zero of the gauge. BASEPLATE of sturdy construction provided with legs.
Additional Information:
- Item Code: DT-56
- Production Capacity: 5000
- Delivery Time: 4 to 6 weeks
- Packaging Details: Wooden Box Packing
Japsin Instrumentation Vacuum Cum Pressure Calibrator With Stand & Isolation Valve
Minimum Order Quantity: 1 Piece
Product Brochure
Model Name/Number | JI-IVLLP-17 |
Brand | "Ji" Japsin Instrumentation |
Material | SS 316 |
Display Type | Digital |
Type | Mechanical |
Accuracy | Depending upon the Master Gauge |
Power Source | mechanical |
Country of Origin | Made in India |
Range: -1 to 7 Kg/Cm2
Easy to Operate & carry
Along with Isolation Valve & Stand.
Accuracy +/- 0.5% FSD
Economical Handheld Calibrator Pneumatic
Additional Information:
- Item Code: 9026
- Production Capacity: 5000
- Delivery Time: 7 Days
Ravika Comparison Pressure Calibrator
Product Brochure
Minimum Order Quantity | 1 Set |
Material | MS |
Display Type | Analog |
Usage/Application | Industrial |
Country of Origin | Made in India |
Model Name/Number | CP Series |
Additional Information:
- Production Capacity: 50
Ji Japsin Instrumentation Portable Digital Calibrator mV/mA/RTD
Product Brochure
Minimum Order Quantity | 1 Piece |
Model Number/Name | JI49PDC |
Brand | Ji |
Usage/Application | Millivolt / MilliAmp/ RTD |
Range | As Per attached Catalog |
Accuracy | 0.05% |
Display Type | Digital |
Instrument Type | Digital |
Calibrated For | Customer Requirement |
Weight | 1 kgs |
I Deal In | New Only |
DISPLAY : 4½ digit 0.5”ht LCDRANGES : 0-±199.99mVDC / 0-±19.999mADC /-100.0°C to + 400.0°CACCURACY : ± 0.05% ± 2 digit for mV/mA /±0.25% ± 2 digit for PT-100 RTDmV/mA/PT - 100 RTD : Selectable by a Push ButtonMILLIVOLT / MILLIAMP : Selectable by a Push ButtonMEASURE / SOURCE : Selectable by a Push ButtonEXTERNAL PT-100 RTD/PT-100RTD SOURCE : Selectable by a Push ButtonMEASURE : Measurement of mV/mA, External PT-100 RTD in °CSOURCE a) Millivolt / Milliamp output adjustable by means of ‘Coarse’& ‘Fine’ Potentiometersb) For PT-100 RTDi) In PT-100 RTD Mode/Measure Mode, the desiredtemperature in °C is adjustable by means of ‘Fine’(PT-100) Potentiometer.ii) In PT-100 Mode/Source Mode, the resistance value correspondingto the “Set Temperature” is available at the output terminals.POWER : 9 V DC Battery (2 Cells)
Additional Information:
- Item Code: JI-23-PDC
- Pay Mode Terms: T/T (Bank Transfer)
- Port of Dispatch: MUMBAI
- Production Capacity: 5000
- Delivery Time: 3 to 4 Days
- Packaging Details: Export Quality
Japsin Instrumentation Handheld Pressure Cum Vacuum Calibrator
Minimum Order Quantity: 1 Piece
Product Brochure
Model Number/Name | JI-LLP-17 |
Brand | "Ji" Japsin Instrumentation |
Application | Industrial |
Usage/Application | Pressure & Vacuum Calibrator |
Range | -1 to 7 Kg/Cm2 |
Accuracy | 0.25% |
Power Source | mechanical |
Warranty | 1 Year Manufacturing warranty |
Weight Kg | 500.00 |
Vacuum Range | Full Vaccum |
I deal in | New Only |
PRINCIPLEIt is a screw type pump used to Measure Low Pressure or Vacuum. It has got two main partsOne Cylinder and A piston with Pushing Screw and Rotating Knob (4)When we Rotate the Knob in the Clock wise Direction Pressure Increases and if was Rotate theKnob in the Anti Clock wise Direction Minus Pressure / Vaccum Develops
Additional Information:
- Item Code: LLP-5
- Production Capacity: 5000
- Delivery Time: 7 days
- Packaging Details: Export Quality
Ji Japsin Instrumentation Portable Thermocouple / RTD Calibrator CUM Thermometer
Product Brochure
Minimum Order Quantity | 1 Piece |
Temperature Range | As Per Attached PDF |
Model Number/Name | JI50PDC |
Brand | "Ji" Japsin Instrumentation |
Usage/Application | Thermocouple & RTD Calibration |
Range | As Per Attached PDF |
Accuracy | 0.05% |
Display Type | Digital, Analog |
I deal in | New Only |
DISPLAY : 4½ digit 0.5”ht LCDRANGES : 0-600.0°C for Fe/ConT/C (J type)0-1200.0°C for Cr/Al T/C (K type)-100.0°C to +400.0°C for PT-100 RTDACCURACY : ±0.25% ± 2 digit for Fe/Con T/C / PT-100 RTD±0.25% ± 2 digit for Cr/Al T/C upto 1000°C±1% ± 2digit above 1000°C for Cr/Al T/CFe/Con T/C/Cr/Al T/CPT-100 RTD : Selectable by a Push ButtonSOURCE : a) Fe/Con T/C / Cr/Al T/C Output adjustable by means of“Coarse” & “Fine” Potentiometers.b) PT-100 RTD output is adjustable by means of“FINE” Potentiometer only.MEASURE : Measurement of external Fe/Con T/C, Cr/Al T/C, PT-100 RTD in °CAUTO CJC : Provided for ThermocouplePOWER : 9 VDC Battery (Two Cell)
Additional Information:
- Item Code: JI50PDC
- Production Capacity: 5000
- Delivery Time: 3 to 4 Days